Installing a residual current device (RCD) in a low-voltage power distribution system is a crucial step in preventing electric shocks and reducing the risk of electrical fires or equipment damage caused by leakage currents. RCDs are typically categorized into one-pole, two-pole, three-pole, and four-pole types. The main distinction between one-pole and two-pole RCDs lies in whether the neutral line is disconnected during a leakage event. Their working principle relies on detecting the phasor difference between the phase and neutral currents, and if this difference exceeds the set threshold, the RCD will trip. This paper focuses on the differences in both the operational principles and applications of three-pole and four-pole RCDs. While reviewing schematics provided by both domestic and international manufacturers, we noticed some discrepancies. Although the four-pole RCD designs appear similar across brands, the three-pole models showed significant variations in structure and application. Before diving deeper, it's important to clarify the concept of "three-phase load balance." In theory, when the three-phase loads are balanced, the sum of the three-phase current phasors should be zero. However, in real-world applications, achieving perfect three-phase balance is rare due to factors like manufacturing tolerances, environmental conditions, and power quality issues. As a result, the actual phasor sum of the three-phase currents (ia, ib, ic) may not be zero and can easily reach the operating threshold of an RCD, such as 30 mA. Therefore, the concept of "three-phase load balance" holds more theoretical than practical value. The basic principle of leakage operation for both three-pole and four-pole RCDs is the same: they monitor the current phasor through a zero-sequence current transformer. If the sum of the three-phase currents and the neutral current (ia + ib + ic + iN) is not zero, the RCD will activate. In a normal three-phase four-wire system, regardless of the load, the sum should always be zero, so the RCD remains inactive. However, during a ground fault, part of the current from the faulty phase flows to earth, causing an imbalance that triggers the RCD and cuts off the circuit, ensuring safety. The key difference between three-pole and four-pole RCDs is whether the neutral line is disconnected along with the phase lines during a trip. Based on this, the author argues that a three-pole RCD is essentially a "false three-pole" device, as its functionality is largely equivalent to that of a four-pole RCD. This distinction has important implications for installation and application, especially in systems where the neutral line must be isolated for safety reasons.

DC Source System

APM DC source system is programmable DC Power Supply which can output high power. Users can set the output voltage,current arbitrarily .Measure all kinds of features and display on VFD. As for this DC source system,output voltage is up to 1200VDC max (recommend not to exceed 800V) by connecting the internal single unit in series.

High voltage dc power supply output current is up to 2000A max by connecting the internal single unit in parallel. Maximum power and height of the adjustable power supply is in 10.8kW, 21.6kW, 36kW and 6U, 12U ,20U high respectively.

Some features as below:


  • With accurate voltage and current measurement capability.
  • Coded Knob, multifunctional keyboard.
  • Standard RS232/RS485/USB/LAN communication interfaces, GPIB is optional.
  • Remote sensing line voltage drop compensation.
  • Equips with LIST waveform editing function.
  • Use the Standard Commands for Programmable Instrumentation(SCPI) communication protocol.
  • Have obtained CE certification.


DC Source System,30V Power Supply,Digital DC Power Supply,Dc Constant Power Source

APM Technologies Ltd , https://www.apmpowersupply.com